  Datasheet File OCR Text:
 File name: TFS140P.doc
version 1.3
02.12.2002
VI TELEFILTER
1. Measurement condition :
Filter specification
TFS 140 P
1/5
Ambient temperature TA: Input power level: Terminating impedances in fc :
45 C 0 dBm for input: for output:
50 50
0 pF. 0 pF.
2.
Characteristics :
Remark: Reference level for the relative attenuation arel of the TFS 140 P is the minimum of the pass band attenuation a min. The minimum of
the pass band attenuation amin is defined as the insertion loss a e. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 6 dB filter attenuation level relative to the insertion loss ae . The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range.
Data
Insertion loss : (Reference level) ae fc fc PB
typ. value 25,8 140,00 140,22 dB MHz MHz
tolerance / limit max. 27 dB MHz
Centre frequency at ambient temperature TA = 45 C : Centre frequency at room temperature TA = 23 C : Pass band : ( see theoretical Pass band tilt :
1)
140 0,15
frequency response)
fC - 9,922 MHz ... fC + 9,922 MHz 0,0 dB/MHz
1)
max.
0,01 dB/MHz
Deviation from theoretical frequency response at ambient temperature T A = 45 C fC - (1-a) fY ... fC + (1-a) fY fC - f Y ... fC + fY or [ fC - 9,922 MHz ... fC + 9,922 MHz ] or [ fC + 12,100 MHz ... fC + 12,100 MHz ] arel 60...45
C
(p-p) : max. 0,2 max. 0,5 min. 40 2 45 45 dB dB dB
0,17 0,3
dB dB
Relative attenuation at ambient temperature : fC 15 MHz .... fC 120 MHz Group delay ( mean value in PB ): Group delay ripple in PB (p-p): Deviation from linear phase in PB : Reflected attenuation compared to main signal Crosstalk attenuation compared to main signal Nyquist frequency Roll-off factor Partitioning factor Input power level Temperature coefficient of frequency : Frequency deviation of f c over temperature : Operating temperature : Operable temperature range : Storage temperature range :
1)
1,3 20 1,5 60 52
s ns degree dB dB MHz
max. min. min.
dB dB
fY a p Tcf
12,10 0,18 0,5
max. - 72 ppm / K fc(Hz) = Tcf(ppm/K) x (T - TA) x fC (MHz) -
15
dBm
+ 45 C - 40 C ... + 85 C - 40 C ... + 85 C
Theoretical frequency response :
H (x)
( S ( x )) 1
p
;
where ,
x
f fY
fC for x (1 (1 a) a) x x (1 (1 a) a ),
S (x)
1 2 0
1 cos 2
(x
1 2a
a)
, for for
Generated:
W. Dunzow
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFS140P.doc
version 1.3
02.12.2002
VI TELEFILTER
3. Construction and pin connection :
24.64
Filter specification
( all dimensions in mm)
TFS 140 P
pin grid 1,91 mm
2/5
TFS
140P P22
Date-code
9.00
Date-code: M N P ...
Year+week 2000 2001 2002 ...
2.62 Max 1.02
1
2
3
4
5
11
Pin 1 Pin 10 Pin 6 Pin 5 Pin 2-4, 7-9
2.31
Input Input RF Return Output Output RF Return Package Ground
10
4.83 x 3.53 1.91
9
8
7
6
1.02
4. 50
matching networks ( please refer to the application note for further details ) :
1
2
3
4
5
50
10
9
8
7
6
50
Scheme 1.
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFS140P.doc
version 1.3
02.12.2002
VI TELEFILTER
5. Stability characteristics :
Filter specification
TFS 140 P
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N
2. Vibration:
3. Change of temperature:
4. Resistance to solder heat (reflow):
reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;
6. Packing :
Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: Trailer 1000 min 300 mm min 500 mm min 300 mm
Tape (all dimensions in mm)
W Po Do E So P2 P1 D1(min) Ao Bo Ko t CT : : : : : : : : : : : : : 44 4 1,5 1,75 40,4 2 16 2,0 9,3 24,9 2,0 0,35 38,0 0,3 0,1 + 0,1 0,1 0,1 0,15 0,1 0,1 0,1 0,1 0,05 0,1
pull off direction
X-X
Po Do P1 P2
t
X
Ko D1 Ao
view direction
X
SPEC-Gurt 0061/ 19X6,5 Q09016:02.001 Jul.10,01
W2
Reel (all dimensions in mm): A W1 W2(max) N(min) C : : : : : 330 44,4 + 2/-0 50,4 100 13,0 +0,5 / -0,2
A
C
N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape in the above shown direction.
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFS140P.doc
version 1.3
02.12.2002
VI TELEFILTER
Filter specification
TFS 140 P
4/5
6. Air reflow temperature conditions :
1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods main-heating periods 150 C - 170 C over 200 C 60 sec. - 90 sec. 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFS140P.doc
version 1.3
02.12.2002
VI TELEFILTER
Filter specification
TFS 140 P
5/5
7. History :
Version 1.0 1.1 Reason of Changes - generate development specification according to customer requirements. Name Dunzow W. Date 25.03.2002
- change pin connection according to customer requirements. Dunzow W. 02.04.2002 - define " Temperature coefficient of frequency" : Tcf =- 72 ppm / K - define " Pass band (PB) " : fC - (1-a) fY ... fC + (1-a) fY or [ fC - 9,922 MHz ... fC + 9,922 MHz ] - define " Deviation from linear phase in PB " : max. 2 - correct "Deviation from theoretical frequency response 1) at ambient temperature TA = 45 C (p-p) " : - add typical value of filter. - change tolerance value for insertion loss: from max. 26 dB to max. 27 dB. Dunzow W. 08.04.2002
1.2
1.3
Dunzow W.
02.12.2002
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS140P

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X